Product Name: | Ventilator Breathing Machine | Type: | Breathing Apparatus |
---|---|---|---|
Power Supply: | AC110~240V, 50Hz/60Hz, 65VA | Measurement Range: | 20-45℃ |
Pulse Range: | 0-300bpm | Pulse Accuracy: | ±2bpm |
High Light: | non invasive breathing machine,ventilator oxygen machine |
Breathing apparatus portable Icu ventilator machine 12.1" TFT LCD screen displays
Main Features
Breathing apparatus portable Icu ventilator machine price
The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Intra-operation, post-operation respiratory support, other respiratory treatment.
Trust Points
1. Simplicity: easy to use, easy to move with 4 wheels.
2. Choice: adapt the equipment to your patients and procedures freely
3. Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 8 modes: IPPV; A/C; PCV; SIMV; SPONT/CPAP;PSV;SIGH;MANU.
4. Designed and manufactured by Perlong Medical with over 23 years experience in this area.
Flexible configurations to suit your needs.
5. International standard and advanced technology suitable for wide range use.
6. Compact interface and big screen give you better operating experience.
7. Over 2,000 units installed in the world.
Features
1. 12.1" TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform.
2. Recycle breathing pipe, ensure easy operating and keep tidy.
3. Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
4. Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.
5. Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;
6. Real time pressure-time, flow-time loop graphics and high precision O2 concentration detection function included.
7. Stable and low noise air compressor, create quiet work environment for doctors.
Specifications
Ventilation modes: | IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV,SIGH,MANU |
Ventilator parameter ranges | |
Tidal volume(Vt) | 0 ~ 2000mL |
Frequency (Freq) | 1bpm ~ 100 bpm |
Oxygen concentration | 21%-100% |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 40 cmH2O |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters | |
Frequency (Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2500 mL |
Oscillographs display: | |
P-T(pressure – time) | |
F-T(flow – time) | |
P-V loop (pressure – volume loop) | |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | ≤11.3±0.3V |
No tidal volume | No tidal volume within 6s |
High Minute Volume alarm | 5L/min-99L/min |
LowMinute Volume alarm | 1L/min-30L/min |
High Airway pressure alarm | 20cmH2O-100cmH2O |
Low Airway pressure alarm | 0cmH2O-20cmH2O |
High oxygen concentration alarm | 19%-100% |
Low oxygen concentration alarm | 18%-99% |
Continuous pressure alarm | (PEEP+1.5cmH2O) over 16s |
Suffocation warning | 5-60s |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
The maximum limited pressure | <12.5 kPa |
Working conditions | |
Gas source | O2,AIR |
Pressure | 280kPa-600kPa |
Voltage | -220V±22V |
Power frequency | 50Hz±1Hz |
Input power | 900VA(with air compressor) |
250VA(without air compressor) |